DKK-TOA CORPORATION

  • Language
    • Japanese
    • English
    • Chinese
    • Other languages
  • Locations
  • Contact Us
  • Our Products
    Our Products
    • Product News
    • Search By Usage
      • Pure Water Measurement
      • Effluent Measurement
      • Total Amount Regulation
    • Search By Field of Use
      • Water supply
      • Sewerage
      • Semiconductor
      • Food industry
      • Aquaculture / Aquarium
    • Search By Measurement Item
      • pH
      • ORP
      • Electric conductivity (Resistivity, Concentration)
      • Dissolved oxygen
      • Residual chlorine
      • Turbidity
      • Chromaticity
      • SS concentration
      • Ions
      • Nitrogen/Phosphorus
      • Organic pollutants (COD)
      • Multi-parameter water quality meter
      • Automatic Titrator
      • Nitric acid/Nitrite
      • Dissolved hydrogen
      • Ozone
    • Search By Category
      • Laboratory analyzers
      • Portable analyzers
      • Basic process analyzers
      • Analyzers for water & waste water treatment
      • Analyzers for boiler water applications
      • Analyzers for oil refineries
      • Water quality analyzers/systems
      • Ambient air/emission gas analyzers
      • Medical equipment
      • Discontinued Products
    • Product Enquiry
  • Product Support
    Product Support
    • Download Catalogue
    • SDS Search
    • Useful information
    • Product Video Content
    • Guide Book
    • Announcement of Discontinuation
    • Announcement of Termination of Maintenance Support
    • Mercury use in our products
  • News Release
    News Release
    • Announcement
    • Product Information
    • Investor Relations
    • Sustainability
    • Exhibitions
    • Others
  • About DKK-TOA
    About DKK-TOA

    About DKK-TOA

    Why Are We Different?

    Our Specialization

    Globalization

    For Our Future

  • Company Profile
    Company Profile

    Message from the President

    DKK-TOA Corporate Video

    • Company Information
      • Board & Committees of Directors
      • History
      • Corporate Structure
    • Management Policy
      • Management Philosophy
      • Corporate Behavior Charter
      • Corporate Governance
      • Material Procurement Basic Policy
      • Medium-Term Management Plan
    • Locations
    • Group Companies
    • Business Information
    • Research and Development

    Company Brochure

  • Sustainability
    Sustainability
    • Sustainability News
    • Basic policy of Sustainability
    • Customers
    • Business partners
    • Employees
    • Community
    • Global environment
    • Shareholders and Investors

    Sustainability
    Report

Our Products

  • Product News
  • Search By Usage
  • Search By Field of Use
  • Search By Measurement Item
  • Search By Category
  • Product Enquiry

Product Support

  • Download Catalogue
  • SDS Search
  • Useful information
  • Product Video Content
  • Guide Book
  • Announcement of Discontinuation
  • Announcement of Termination of Maintenance Support
  • Mercury use in our products

News Release

  • Announcement
  • Product Information
  • Investor Relations
  • Sustainability
  • Exhibitions
  • Others

About DKK-TOA

  • About DKK-TOA
  • Why Are We Different?
  • Our Specialization
  • Globalization
  • For Our Future

Company Profile

  • Message from the President
  • Company Information
  • Management Policy
  • Locations
  • Group Companies
  • Business Information
  • Research and Development

Sustainability

  • Sustainability News
  • Basic policy of Sustainability
  • Customers
  • Business partners
  • Employees
  • Community
  • Global environment
  • Shareholders and Investors
  • Sustainability Report
Close

Our Products

  1. Top
  2. Our Products
  3. Electric Conductivity Cell for X series

Electric Conductivity Cell for X series

Product Name Immersion type conductivity cell "CALMEMO"  Immersion type conductivity cell
Model For general use
CT-58101B
For low electric conductivity
CT-58101C
For high electric conductivity
CT-58101A
For general use
C-50101B
dimensional drawing
measurement range electric conductivity 100μS/m〜10S/m
{1μS/cm〜100mS/cm}
5μS/m〜1S/m
{0.05μS/cm〜10mS/cm}
1mS/m〜100S/m
{10μS/cm〜1S/cm}
100μS/m〜10S/m
{1μS/cm〜100mS/cm}
temperature 0〜100℃ 0〜100℃ 0〜100℃ ─
cell constant 100m-1 10m-1 1000m-1 100m-1
required amount of specimen * 4mL (Φ14mm×26mm
or more)
6mL (Φ14mm×42mm
or more)
39mL (Φ36mm×38mm
or more)
4mL (Φ14mm×26mm
or more)
temperature sensor ○ ○ ○ ─
remarks JP17 designated cell
The cell constants were determined using standard solution of potassium chloride (1408μS/cm at 25℃) according to JIS K 0130 .
JP17 designated cell
The cell constants were determined using standard solution of potassium chloride (146.5μS/cm at 25℃) according to JIS K 0130 .
─ ─

Product Name flow-type electric conductivity cell "CALMEMO"
Model for general use
CT-88101B
for low electric conductivity
CT-88101C
for high electric conductivity
CT-88102A
for purified water
CT-27111D
(flow cell is not included)
dimensional drawing 
measurement range electric conductivity 100μS/m〜10S/m
{1μS/cm〜100mS/cm}
5μS/m〜1S/m
{0.05μS/cm〜10mS/cm}
10mS/m〜100S/m
{100μS/cm〜1S/cm}
5μS/m〜20mS/m
{0.05μS/cm〜200μS/cm}
temperature 0〜100℃ 0〜100℃ 0〜100℃ 0〜80℃
cell constant 100m-1 10m-1 2000m-1 1m-1
temperature sensor ○ ○ ○ ○
Remarks 4mL required in cell 15mL required in cell.
It is possible to measure low electric conductivity as there is no effect from carbon dioxide.
1mL required in cell.
Flow cell for a small amount.
Dropper rubber and pump tube are required separately.
8mL required in flow cell.
Flow cell is required separately.
PP made (CEF-22A)
(connecting port diameter: outside diameter 8mm × internal diameter 4mm)

SUS made (CEF-23A)
(connecting port diameter: outside diameter 8mm × internal diameter 6mm)
"CALMEMO": The sensor itself stores the model and serial number.
As cell constant is also stored in memory, it reads the cell constant automatically when you connect the cell to the main unit.

  • * The capacity when using the smallest container that can be inserted into a cell. Do not make a suddenly change of temperature of 50℃ or more.

Our Products

  • Search By Usage
  • Search By Measurement Application
  • Search By Measuring Item
  • Search By Category
  • Product Enquiry

Product Support

  • Download Catalogue
  • SDS Search
  • Useful Information
  • Product Video Content
  • Guide Book
  • Announcement of Discontinuation
  • Announcement of Termination of Maintenance Support
  • Mercury use in our products

News Release

  • Announcement
  • Product Information
  • Investor Relations
  • Sustainability
  • Exhibitions
  • Others

About DKK-TOA

  • About DKK-TOA
  • Why Are We Different?
  • Our Specialization
  • Globalization
  • For Our Future

Company Profile

  • Message from the President
  • Company Information
  • Management Policy
  • Locations
  • Group Companies
  • Business Information
  • Research and Development

Sustainability

  • Basic policy of Sustainability
  • Customers
  • Business partners
  • Employees
  • Community
  • Global environment
  • Shareholders and Investors
  • Sustainability Report

Contact Us

  • Product Enquiry
  • Japanese
  • English
  • Chinese
  • Other languages
Go to top
  • Site Map
  • Privacy Policy

DKK-TOA CORPORATION

All Rights Reserved, Copyright(c) DKK-TOA CORPORATION