DKK-TOA CORPORATION

  • Language
    • Japanese
    • English
    • Chinese
    • Other languages
  • Locations
  • Contact Us
  • Our Products
    Our Products
    • Product News
    • Search By Usage
      • Pure Water Measurement
      • Effluent Measurement
      • Total Amount Regulation
    • Search By Field of Use
      • Water supply
      • Sewerage
      • Semiconductor
      • Food industry
      • Aquaculture / Aquarium
    • Search By Measurement Item
      • pH
      • ORP
      • Electric conductivity (Resistivity, Concentration)
      • Dissolved oxygen
      • Residual chlorine
      • Turbidity
      • Chromaticity
      • SS concentration
      • Ions
      • Nitrogen/Phosphorus
      • Organic pollutants (COD)
      • Multi-parameter water quality meter
      • Automatic Titrator
      • Nitric acid/Nitrite
      • Dissolved hydrogen
      • Ozone
    • Search By Category
      • Laboratory analyzers
      • Portable analyzers
      • Basic process analyzers
      • Analyzers for water & waste water treatment
      • Analyzers for boiler water applications
      • Analyzers for oil refineries
      • Water quality analyzers/systems
      • Ambient air/emission gas analyzers
      • Medical equipment
      • Discontinued Products
    • Product Enquiry
  • Product Support
    Product Support
    • Download Catalogue
    • SDS Search
    • Useful information
    • Product Video Content
    • Guide Book
    • Announcement of Discontinuation
    • Announcement of Termination of Maintenance Support
    • Mercury use in our products
  • News Release
    News Release
    • Announcement
    • Product Information
    • Investor Relations
    • Sustainability
    • Exhibitions
    • Others
  • About DKK-TOA
    About DKK-TOA

    About DKK-TOA

    Why Are We Different?

    Our Specialization

    Globalization

    For Our Future

  • Company Profile
    Company Profile

    Message from the President

    DKK-TOA Corporate Video

    • Company Information
      • Board & Committees of Directors
      • History
      • Corporate Structure
    • Management Policy
      • Management Philosophy
      • Corporate Behavior Charter
      • Corporate Governance
      • Material Procurement Basic Policy
      • Medium-Term Management Plan
    • Locations
    • Group Companies
    • Business Information
    • Research and Development

    Company Brochure

  • Sustainability
    Sustainability
    • Sustainability News
    • Basic policy of Sustainability
    • Customers
    • Business partners
    • Employees
    • Community
    • Global environment
    • Shareholders and Investors

    Sustainability
    Report

Our Products

  • Product News
  • Search By Usage
  • Search By Field of Use
  • Search By Measurement Item
  • Search By Category
  • Product Enquiry

Product Support

  • Download Catalogue
  • SDS Search
  • Useful information
  • Product Video Content
  • Guide Book
  • Announcement of Discontinuation
  • Announcement of Termination of Maintenance Support
  • Mercury use in our products

News Release

  • Announcement
  • Product Information
  • Investor Relations
  • Sustainability
  • Exhibitions
  • Others

About DKK-TOA

  • About DKK-TOA
  • Why Are We Different?
  • Our Specialization
  • Globalization
  • For Our Future

Company Profile

  • Message from the President
  • Company Information
  • Management Policy
  • Locations
  • Group Companies
  • Business Information
  • Research and Development

Sustainability

  • Sustainability News
  • Basic policy of Sustainability
  • Customers
  • Business partners
  • Employees
  • Community
  • Global environment
  • Shareholders and Investors
  • Sustainability Report
Close

Our Products

  1. Top
  2. Our Products
  3. HM-40P
  4. ion electrode for HM-40P

ion electrode for HM-40P

electrode name model measurement range / optimum pH range
fluoride ion composite electrode /
ion exchange tip (solid membrane)
 F-2021
 F-200
0.019〜19,000mg/L F-
pH5〜pH6
chloride ion composite electrode /
ion exchange tip (solid membrane)
 CL-2021
 CL-200B
1〜35,000mg/L Cl-
pH5〜pH6
cyanide ion composite electrode /
ion exchange tip (solid membrane)
 CN-2021
 CN-200B
0.003〜26mg/L CN-
pH12〜pH13
sodium ion composite electrode /
ion exchange tip (glass membrane)
 NA-2011
 NA-100B
2.3〜23,000mg/L Na+
pH10〜pH11
potassium ion composite electrode /
ion exchange tip (liquid film)
 K-2031
 K-300B
0.39〜3,900mg/L K+
pH5〜pH6
calcium ion composite electrode /
ion exchange tip (liquid film)
 CA-2031
 CA-300
0.4〜40,000mg/L Ca2+
pH5〜pH6
nitric acid ion composite electrode /
ion exchange tip (liquid film)
 N-2031
 N-300
0.62〜62,000mg/L NO3-
pH5〜pH6
ammonia electrode (diaphragm electrode)  AE-2041 0.09〜1,800mg/L NH4+
pH12 or more
carbon dioxide electrode (diaphragm electrode)  CE-2041 dissolved gas: 1.49〜1,490mg/L
calibration cell (CGC-202L) and calibration adapter (6791140K) are required separately.
bromide ion composite electrode /
ion exchange tip (solid membrane)
 BR-2021
 BR-200
0.8〜80,000mg/L Br-
pH5〜pH6
iodide ion composite electrode /
ion exchange tip (solid membrane)
 I-2021
 I-200
0.01〜127,000mg/L I-
pH5〜pH6
cadmium ion composite electrode /
ion exchange tip (solid membrane)
 CD-2021
 CD-200
0.01〜1,120mg/L Cd2+
pH5〜pH6
copper ion composite electrode /
ion exchange tip (solid membrane)
 CU-2021
 CU-200
0.06〜630mg/L Cu2+
pH5〜pH6
silver ion composite electrode /
ion exchange tip (solid membrane)
 AG-2021
 AG-200
0.1〜108,000mg/L Ag+
pH5〜pH6
sulfide ion composite electrode /
ion exchange tip (solid membrane)
 S-2021
 S-200
0.3〜32,000mg/L S2-
pH13 or more

10 replacement liquid junction for ion sensor for ion electrodes excluding AE-2041/CE-2041  0LF00001
10 exchange membranes for ammonia electrode for AE-2041  AE-FILM
4 diaphragm cartridges for carbon dioxide electrode for CE-2041  CTC-211
carbon dioxide electrode for CE-2041  CGC-202L
calibration adapter for carbon dioxide electrode for CE-2041  6791140K

ion composite electrode geometry
 F-2021、CL-2021、CN-2021、NA-2011、K-2031、
 CA-2031、N-2031、BR-2021、I-2021、CD-2021、
 CU-2021、AG-2021、S-2021
AE-2041 CE-2041
  • * In the case where concentrations of coexisting ions affect the measured value, careful treatment is required to prevent any interference.
  • * This electrode does not support waterproof function and temperature measurement function. The measurable solution temperature range is from 0 to 50℃.
  • In basic, the batch measurement method is used in a beaker after sampling to measure ions.
  • * In addition to the electrodes, standard solutions, ionic strength regulators, reference electrode outer cylinder liquids and electrode holder / stand are required for ion
  • * Please contact us in advance because it may be difficult to measure ions due to sample properties of coexisting ions, etc.

Our Products

  • Search By Usage
  • Search By Measurement Application
  • Search By Measuring Item
  • Search By Category
  • Product Enquiry

Product Support

  • Download Catalogue
  • SDS Search
  • Useful Information
  • Product Video Content
  • Guide Book
  • Announcement of Discontinuation
  • Announcement of Termination of Maintenance Support
  • Mercury use in our products

News Release

  • Announcement
  • Product Information
  • Investor Relations
  • Sustainability
  • Exhibitions
  • Others

About DKK-TOA

  • About DKK-TOA
  • Why Are We Different?
  • Our Specialization
  • Globalization
  • For Our Future

Company Profile

  • Message from the President
  • Company Information
  • Management Policy
  • Locations
  • Group Companies
  • Business Information
  • Research and Development

Sustainability

  • Basic policy of Sustainability
  • Customers
  • Business partners
  • Employees
  • Community
  • Global environment
  • Shareholders and Investors
  • Sustainability Report

Contact Us

  • Product Enquiry
  • Japanese
  • English
  • Chinese
  • Other languages
Go to top
  • Site Map
  • Privacy Policy

DKK-TOA CORPORATION

All Rights Reserved, Copyright(c) DKK-TOA CORPORATION